Inverter SOLAX X3-NEO-8K-LV

SKU: F20S11-2 EAN: 2010000034262
Rated power

Power supply

Urządzenie hybrydowe

MPPT

2

AFCI

Optional

Gwarancja

Szerokość netto

Głębokość netto

Wysokość netto

Wi-Fi

Yes

RS485

Yes

CAN

Yes

USB

Yes

LAN

Yes

DRM

Yes

SPD Type II

Tryb pracy off-grid

Zakres napięcia MPPT

Weight 44,38 kg
CN 85044085
Price 1 776,92 
Gross

1 776,92 
Gross

Email when stock available

1 776,92 
Gross

Email when stock available

Product details

Rated power

Power supply

Urządzenie hybrydowe

MPPT

2

AFCI

Optional

Gwarancja

Szerokość netto

Głębokość netto

Wysokość netto

Wi-Fi

Yes

RS485

Yes

CAN

Yes

USB

Yes

LAN

Yes

DRM

Yes

SPD Type II

Tryb pracy off-grid

Zakres napięcia MPPT

Weight 44,38 kg
CN 85044085

X3-NEO-LV Hybrid Inverter

The X3-NEO-LV series hybrid inverters are three-phase, low-voltage devices designed for residential use, available in power options ranging from 5 to 15 kW. They combine intelligent energy management, high efficiency, and reliability, offering a comprehensive solution for storing and utilizing solar energy. With these inverters, you can optimize PV power usage and ensure a stable power supply under any conditions.

Key Features of the X3-NEO-LV Hybrid Inverter:

  • Fast Switching Time: Emergency power supply (EPS) switching time under 1 ms, ensuring uninterrupted power.
  • High Efficiency and Power Flexibility: Supports up to 200% PV power overload and AC output up to 110%, with the ability to reach 200% peak EPS power for 10 seconds.
  • Advanced Energy Management: Global MPP scanning for optimal energy harvesting and maximum battery charge/discharge current ranging from 125 A to 300 A.
  • Reliable Operation: IP65 protection rating and integrated Type II SPD surge protection on both AC and DC sides, guaranteeing durability and safety across a wide temperature range from -25 to 60°C.
  • Installation Flexibility: Can connect up to 10 units in parallel, both grid-tied and off-grid, featuring microgrid and generator modes for versatile operation.
  • Compatibility with High-Power Panels: Maximum DC input current per MPPT up to 36 A, optimized for modern high-power solar panels.

Who Is This a Good Fit For?

The X3-NEO-LV inverters are an ideal choice for single-family homeowners and small commercial properties seeking a reliable and efficient energy management system. They are perfect for those wanting to maximize self-consumption of solar energy, ensure emergency power (EPS) with ultra-fast switching, and enjoy flexibility in expanding their photovoltaic system. Their high efficiency, robust protections, and intelligent communication features make them a comprehensive energy hub for the modern household.

Parameter X3-NEO-5K-LV X3-NEO-8K-LV X3-NEO-10K-LV X3-NEO-12K-LV X3-NEO-15K-LV
PV INPUT
Max. recommended PV panel array power (kWp) 10 16 20 24 30
Max. PV input voltage (V) 1000 1000 1000 1000 1000
Nominal PV input voltage (V) 640 640 640 640 640
Operating voltage range (V) 160-950 160-950 160-950 160-950 160-950
MPPT voltage range (V) 160-950 160-950 160-950 160-950 160-950
Starting voltage (V) 150 150 150 150 150
Number of MPP trackers / strings per MPP tracker 2/(1/1) 2/(1/1) 2/(2/1) 2/(2/1) 2/(2/2)
Max. input current per MPPT (MPPT1/2) (A) 18/18 18/18 36/18 36/18 36/36
Max. short-circuit input current per MPPT (MPPT1/2) (A) 25/25 25/25 50/25 50/25 50/50
AC INPUT AND OUTPUT (GRID-TIED)
Rated output power (kW) 5 8 10 12 15
Rated output current (A) 7.3 11.6 14.5 15.3 17.4
Max. apparent output power (kVA) 5.5 8.8 11 13.2 16.5
Max. continuous output current (A) 8.4 13.4 16.8 20.0 25.0
Rated AC voltage (V) 3/N/PE, 220/380V
3/N/PE, 230/400V
3/N/PE, 220/380V
3/N/PE, 230/400V
3/N/PE, 220/380V
3/N/PE, 230/400V
3/N/PE, 220/380V
3/N/PE, 230/400V
3/N/PE, 220/380V
3/N/PE, 230/400V
Max. AC input apparent power (kVA) 10 16 20 24 30
Max. AC input current (A) 15.2 24.3 30.4 36.4 45.5
Rated AC frequency (Hz) 50/60 50/60 50/60 50/60 50/60
AC frequency range (Hz) 50±5 / 60±5 50±5 / 60±5 50±5 / 60±5 50±5 / 60±5 50±5 / 60±5
Adjustable power factor range -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading)
THDi (rated power) (%) <3 <3 <3 <3 <3
BATTERY
Battery type Lithium battery / lead-acid battery Lithium battery / lead-acid battery Lithium battery / lead-acid battery Lithium battery / lead-acid battery Lithium battery / lead-acid battery
Battery voltage range (V) 40-60 40-60 40-60 40-60 40-60
Max. charging / discharging current (A) 125 200 250 280 300
EPS OUTPUT (OFF-GRID) (WITH BATTERY)
Rated EPS output power (kVA) 5 8 10 12 15
Peak EPS output power 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s
Switching time (ms) <1 <1 <1 <1 <1
EFFICIENCY
Max. efficiency (%) 97.6 97.6 97.6 97.6 97.6
European efficiency (%) 97.0 97.0 97.0 97.0 97.0
ENVIRONMENTAL LIMITS
Protection rating IP65 IP65 IP65 IP65 IP65
Operating ambient temperature range (°C) -25 to 60 -25 to 60 -25 to 60 -25 to 60 -25 to 60
Max. operating altitude (m) 3000 3000 3000 3000 3000
Relative humidity (% RH) 4-100 (condensing) 4-100 (condensing) 4-100 (condensing) 4-100 (condensing) 4-100 (condensing)
Surge category Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II
GENERAL
Dimensions (W × H × D) (mm) 520 × 705 × 258 520 × 705 × 258 520 × 705 × 258 520 × 705 × 258 520 × 705 × 258
Net weight (kg) 44.6 44.6 44.6 44.6 44.6
Cooling concept Intelligent cooling Intelligent cooling Intelligent cooling Intelligent cooling Intelligent cooling
Communication interfaces LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN
Power consumption (night) (W) <15 <15 <15 <15 <15
Topology Non-isolated Non-isolated Non-isolated Non-isolated Non-isolated
Certifications and approvals EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS
PROTECTION
Protections Overvoltage / undervoltage protection, DC insulation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse current monitoring, residual current detection, over-temperature protection Overvoltage / undervoltage protection, DC insulation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse current monitoring, residual current detection, over-temperature protection Overvoltage / undervoltage protection, DC insulation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse current monitoring, residual current detection, over-temperature protection Overvoltage / undervoltage protection, DC insulation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse current monitoring, residual current detection, over-temperature protection Overvoltage / undervoltage protection, DC insulation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse current monitoring, residual current detection, over-temperature protection
Active anti-islanding method Frequency shift Frequency shift Frequency shift Frequency shift Frequency shift
Surge protection (DC / AC) DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II

(1) Maximum DC input voltage is the upper limit. Higher DC input voltage may damage the inverter.
(2) Input voltage exceeding the MPPT voltage range may trigger inverter protections.
(3) AC frequency range may vary depending on national requirements.
(4) Power derating above +45°C.

Official distribution