Inverter SOLAX X3-NEO-5K-LV
Manufacturer | |
---|---|
Rated power | |
Power supply | |
Urządzenie hybrydowe | |
MPPT | 2 |
AFCI | Optional |
Gwarancja | |
Szerokość netto | |
Głębokość netto | |
Wysokość netto | |
Wi-Fi | Yes |
RS485 | Yes |
CAN | Yes |
USB | Yes |
LAN | Yes |
DRM | Yes |
SPD Type II | |
Tryb pracy off-grid | |
Zakres napięcia MPPT | |
Weight | 44,34 kg |
CN | 85044085 |
Gross
Email when stock available
Email when stock available
Product details
Manufacturer | |
---|---|
Rated power | |
Power supply | |
Urządzenie hybrydowe | |
MPPT | 2 |
AFCI | Optional |
Gwarancja | |
Szerokość netto | |
Głębokość netto | |
Wysokość netto | |
Wi-Fi | Yes |
RS485 | Yes |
CAN | Yes |
USB | Yes |
LAN | Yes |
DRM | Yes |
SPD Type II | |
Tryb pracy off-grid | |
Zakres napięcia MPPT | |
Weight | 44,34 kg |
CN | 85044085 |
Hybrid Inverter X3-NEO-LV
The X3-NEO-LV series hybrid inverters are three-phase, low-voltage devices designed for residential use, available in power variants ranging from 5 to 15 kW. They combine intelligent energy management, high efficiency, and reliability, offering a comprehensive solution for storing and utilizing solar energy. With these inverters, you can optimize PV power usage and ensure power supply protection under all conditions.
Key Features of the Hybrid Inverter X3-NEO-LV:
- Fast Switching Time: Emergency power supply (EPS) switching time below 1 ms, ensuring continuous power supply.
- High Efficiency and Power Flexibility: Supports up to 200% PV power surplus and AC output up to 110%, with the ability to reach 200% EPS peak power for 10 seconds.
- Advanced Energy Management: Global MPP scanning for optimal energy harvesting and maximum battery charge/discharge current ranging from 125 A to 300 A.
- Reliable Protection: IP65 protection rating and integrated Type II SPD protection on both AC and DC sides, ensuring durability and safe operation in a wide temperature range from -25 to 60°C.
- Installation Flexibility: Can connect up to 10 units in parallel in both grid-tied and off-grid modes, featuring microgrid and generator modes for versatile operation.
- Compatible with High-Power Panels: Maximum DC input current per MPPT up to 36 A, optimized for modern high-power solar panels.
Who Is This a Good Choice For?
The X3-NEO-LV series inverters are an ideal solution for homeowners and small commercial properties looking for a reliable and efficient energy management system. They are perfect for those aiming to maximize self-consumption of solar energy, ensure emergency power supply (EPS) with ultra-fast switching, and enjoy flexibility in expanding their photovoltaic system. Their high efficiency, robust protections, and smart communication features make them a comprehensive energy hub for a modern household.
Parameter | X3-NEO-5K-LV | X3-NEO-8K-LV | X3-NEO-10K-LV | X3-NEO-12K-LV | X3-NEO-15K-LV |
---|---|---|---|---|---|
PV INPUT | |||||
Max. recommended PV panel array power (kWp) | 10 | 16 | 20 | 24 | 30 |
Max. PV input voltage (V) | 1000 | 1000 | 1000 | 1000 | 1000 |
Rated PV input voltage (V) | 640 | 640 | 640 | 640 | 640 |
Operating voltage range (V) | 160-950 | 160-950 | 160-950 | 160-950 | 160-950 |
MPPT voltage range (V) | 160-950 | 160-950 | 160-950 | 160-950 | 160-950 |
Starting voltage (V) | 150 | 150 | 150 | 150 | 150 |
Number of MPP trackers / strings per MPP tracker | 2/(1/1) | 2/(1/1) | 2/(2/1) | 2/(2/1) | 2/(2/2) |
Max. input current per MPPT (MPPT1/2) (A) | 18/18 | 18/18 | 36/18 | 36/18 | 36/36 |
Max. short-circuit input current per MPPT (MPPT1/2) (A) | 25/25 | 25/25 | 50/25 | 50/25 | 50/50 |
AC INPUT AND OUTPUT (GRID-TIED) | |||||
Rated output power (kW) | 5 | 8 | 10 | 12 | 15 |
Rated output current (A) | 7.3 | 11.6 | 14.5 | 15.3 | 17.4 |
Max. apparent output power (kVA) | 5.5 | 8.8 | 11 | 13.2 | 16.5 |
Max. continuous output current (A) | 8.4 | 13.4 | 16.8 | 20.0 | 25.0 |
Rated AC voltage (V) | 3/N/PE, 220/380V 3/N/PE, 230/400V |
3/N/PE, 220/380V 3/N/PE, 230/400V |
3/N/PE, 220/380V 3/N/PE, 230/400V |
3/N/PE, 220/380V 3/N/PE, 230/400V |
3/N/PE, 220/380V 3/N/PE, 230/400V |
Max. apparent AC input power (kVA) | 10 | 16 | 20 | 24 | 30 |
Max. AC input current (A) | 15.2 | 24.3 | 30.4 | 36.4 | 45.5 |
Rated AC frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
AC frequency range (Hz) | 50±5 / 60±5 | 50±5 / 60±5 | 50±5 / 60±5 | 50±5 / 60±5 | 50±5 / 60±5 |
Adjustable power factor range | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) |
THDi (rated power) (%) | <3 | <3 | <3 | <3 | <3 |
BATTERY | |||||
Battery type | Lithium battery / Lead-acid battery | Lithium battery / Lead-acid battery | Lithium battery / Lead-acid battery | Lithium battery / Lead-acid battery | Lithium battery / Lead-acid battery |
Battery voltage range (V) | 40-60 | 40-60 | 40-60 | 40-60 | 40-60 |
Max. charge/discharge current (A) | 125 | 200 | 250 | 280 | 300 |
EPS OUTPUT (OFF-GRID) (WITH BATTERY) | |||||
Rated EPS output power (kVA) | 5 | 8 | 10 | 12 | 15 |
Peak EPS output power | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s |
Switching time (ms) | <1 | <1 | <1 | <1 | <1 |
EFFICIENCY | |||||
Max. efficiency (%) | 97.6 | 97.6 | 97.6 | 97.6 | 97.6 |
European efficiency (%) | 97.0 | 97.0 | 97.0 | 97.0 | 97.0 |
ENVIRONMENTAL LIMITS | |||||
Protection degree | IP65 | IP65 | IP65 | IP65 | IP65 |
Operating ambient temperature range (°C) | -25 to 60 | -25 to 60 | -25 to 60 | -25 to 60 | -25 to 60 |
Max. operating altitude (m) | 3000 | 3000 | 3000 | 3000 | 3000 |
Relative humidity (% RH) | 4-100 (condensing) | 4-100 (condensing) | 4-100 (condensing) | 4-100 (condensing) | 4-100 (condensing) |
Surge category | Grid: III, Battery: II, PV: II | Grid: III, Battery: II, PV: II | Grid: III, Battery: II, PV: II | Grid: III, Battery: II, PV: II | Grid: III, Battery: II, PV: II |
GENERAL | |||||
Dimensions (W × H × D) (mm) | 520 × 705 × 258 | 520 × 705 × 258 | 520 × 705 × 258 | 520 × 705 × 258 | 520 × 705 × 258 |
Net weight (kg) | 44.6 | 44.6 | 44.6 | 44.6 | 44.6 |
Cooling concept | Intelligent cooling | Intelligent cooling | Intelligent cooling | Intelligent cooling | Intelligent cooling |
Communication interfaces | LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN | LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN | LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN | LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN | LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN |
Power consumption (night) (W) | <15 | <15 | <15 | <15 | <15 |
Topology | Non-isolated | Non-isolated | Non-isolated | Non-isolated | Non-isolated |
Certifications and approvals | EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS | EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS | EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS | EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS | EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS |
PROTECTION | |||||
Protections | Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse leakage current monitoring, residual current detection, over-temperature protection | Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse leakage current monitoring, residual current detection, over-temperature protection | Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse leakage current monitoring, residual current detection, over-temperature protection | Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse leakage current monitoring, residual current detection, over-temperature protection | Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse leakage current monitoring, residual current detection, over-temperature protection |
Active anti-islanding method | Frequency shift | Frequency shift | Frequency shift | Frequency shift | Frequency shift |
Surge protection (DC / AC) | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II |
(1) Maximum DC input voltage is the upper limit. Higher DC input voltage may damage the inverter.
(2) Input voltage exceeding the MPPT voltage range may trigger inverter protections.
(3) AC frequency range may vary depending on national requirements.
(4) Power derating above +45°C.