Inverter SOLAX X3-NEO-15K-LV

SKU: F20S125 EAN: 2010000034293
Manufacturer

Rated power

Power supply

Urządzenie hybrydowe

MPPT

2

AFCI

Optional

Gwarancja

Szerokość netto

Głębokość netto

Wysokość netto

Wi-Fi

Yes

RS485

Yes

CAN

Yes

USB

Yes

LAN

Yes

DRM

Yes

SPD Type II

Tryb pracy off-grid

Zakres napięcia MPPT

Weight 51,14 kg
CN 85044085
Price 2 147,11 
Gross

2 147,11 
Gross

In stock:

1 pcs
Login to place an order

2 147,11 
Gross

In stock:

1 pcs
Login to place an order

Product details

Manufacturer

Rated power

Power supply

Urządzenie hybrydowe

MPPT

2

AFCI

Optional

Gwarancja

Szerokość netto

Głębokość netto

Wysokość netto

Wi-Fi

Yes

RS485

Yes

CAN

Yes

USB

Yes

LAN

Yes

DRM

Yes

SPD Type II

Tryb pracy off-grid

Zakres napięcia MPPT

Weight 51,14 kg
CN 85044085

X3-NEO-LV Hybrid Inverter

The X3-NEO-LV series hybrid inverters are three-phase, low-voltage devices designed for residential use, available in power variants ranging from 5 to 15 kW. They combine intelligent energy management, high efficiency, and reliability, offering a comprehensive solution for storing and utilizing solar energy. With these inverters, you can optimize PV power usage and ensure power supply security under any conditions.

Key Features of the X3-NEO-LV Hybrid Inverter:

  • Fast switching time: Emergency power supply (EPS) switching time under 1 ms, ensuring uninterrupted power.
  • High efficiency and power flexibility: Supports up to 200% PV power overload and AC output up to 110%, with the ability to reach 200% EPS peak power for 10 seconds.
  • Advanced energy management: Global MPP scanning for optimal energy harvesting and a maximum battery charge/discharge current ranging from 125 A to 300 A.
  • Reliable operation guaranteed: IP65 protection rating and integrated Type II SPD protection on AC and DC sides, ensuring durability and safe operation across a wide temperature range from -25 to 60°C.
  • Installation flexibility: Ability to connect up to 10 units in parallel both on-grid and off-grid, with microgrid and generator mode functions for versatile operation.
  • Compatibility with high-power panels: Maximum DC input current per MPPT up to 36 A, optimized for modern high-power solar panels.

Who is this a good choice for?

The X3-NEO-LV series inverters are an ideal solution for homeowners and small commercial properties seeking a reliable and efficient energy management system. They are perfect for those aiming to maximize self-consumption of solar energy, ensure emergency power supply (EPS) with ultra-fast switching, and gain flexibility in expanding their photovoltaic system. Their high efficiency, robust protections, and intelligent communication features make them a comprehensive energy hub for the modern household.

Parameter X3-NEO-5K-LV X3-NEO-8K-LV X3-NEO-10K-LV X3-NEO-12K-LV X3-NEO-15K-LV
PV INPUT
Max. recommended PV panel array power (kWp) 10 16 20 24 30
Max. PV input voltage (V) 1000 1000 1000 1000 1000
Rated PV input voltage (V) 640 640 640 640 640
Operating voltage range (V) 160-950 160-950 160-950 160-950 160-950
MPPT voltage range (V) 160-950 160-950 160-950 160-950 160-950
Starting voltage (V) 150 150 150 150 150
Number of MPP trackers / strings per MPP tracker 2/(1/1) 2/(1/1) 2/(2/1) 2/(2/1) 2/(2/2)
Max. input current per MPPT (MPPT1/2) (A) 18/18 18/18 36/18 36/18 36/36
Max. short-circuit input current per MPPT (MPPT1/2) (A) 25/25 25/25 50/25 50/25 50/50
AC INPUT & OUTPUT (GRID)
Rated output power (kW) 5 8 10 12 15
Rated output current (A) 7.3 11.6 14.5 15.3 17.4
Max. output apparent power (kVA) 5.5 8.8 11 13.2 16.5
Max. continuous output current (A) 8.4 13.4 16.8 20.0 25.0
Rated AC voltage (V) 3/N/PE, 220/380V
3/N/PE, 230/400V
3/N/PE, 220/380V
3/N/PE, 230/400V
3/N/PE, 220/380V
3/N/PE, 230/400V
3/N/PE, 220/380V
3/N/PE, 230/400V
3/N/PE, 220/380V
3/N/PE, 230/400V
Max. AC input apparent power (kVA) 10 16 20 24 30
Max. AC input current (A) 15.2 24.3 30.4 36.4 45.5
Rated AC frequency (Hz) 50/60 50/60 50/60 50/60 50/60
AC frequency range (Hz) 50±5 / 60±5 50±5 / 60±5 50±5 / 60±5 50±5 / 60±5 50±5 / 60±5
Adjustable power factor range -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading)
THDi (rated power) (%) <3 <3 <3 <3 <3
BATTERY
Battery type Lithium / Lead-acid battery Lithium / Lead-acid battery Lithium / Lead-acid battery Lithium / Lead-acid battery Lithium / Lead-acid battery
Battery voltage range (V) 40-60 40-60 40-60 40-60 40-60
Max. charging / discharging current (A) 125 200 250 280 300
EPS OUTPUT (OFF-GRID) (WITH BATTERY)
Rated EPS output power (kVA) 5 8 10 12 15
Peak EPS output power 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s
Switching time (ms) <1 <1 <1 <1 <1
EFFICIENCY
Max. efficiency (%) 97.6 97.6 97.6 97.6 97.6
European efficiency (%) 97.0 97.0 97.0 97.0 97.0
ENVIRONMENTAL LIMITS
Protection rating IP65 IP65 IP65 IP65 IP65
Operating ambient temperature range (°C) -25 to 60 -25 to 60 -25 to 60 -25 to 60 -25 to 60
Max. operating altitude (m) 3000 3000 3000 3000 3000
Relative humidity (% RH) 4-100 (condensing) 4-100 (condensing) 4-100 (condensing) 4-100 (condensing) 4-100 (condensing)
Surge category Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II
GENERAL
Dimensions (W × H × D) (mm) 520 × 705 × 258 520 × 705 × 258 520 × 705 × 258 520 × 705 × 258 520 × 705 × 258
Net weight (kg) 44.6 44.6 44.6 44.6 44.6
Cooling concept Intelligent cooling Intelligent cooling Intelligent cooling Intelligent cooling Intelligent cooling
Communication interfaces LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN
Power consumption (night) (W) <15 <15 <15 <15 <15
Topology Non-isolated Non-isolated Non-isolated Non-isolated Non-isolated
Certifications and approvals EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS
PROTECTION
Protective features Overvoltage / undervoltage protection, DC insulation monitoring, DC reverse polarity protection, grid monitoring, DC injection monitoring, return current monitoring, residual current detection, over temperature protection Overvoltage / undervoltage protection, DC insulation monitoring, DC reverse polarity protection, grid monitoring, DC injection monitoring, return current monitoring, residual current detection, over temperature protection Overvoltage / undervoltage protection, DC insulation monitoring, DC reverse polarity protection, grid monitoring, DC injection monitoring, return current monitoring, residual current detection, over temperature protection Overvoltage / undervoltage protection, DC insulation monitoring, DC reverse polarity protection, grid monitoring, DC injection monitoring, return current monitoring, residual current detection, over temperature protection Overvoltage / undervoltage protection, DC insulation monitoring, DC reverse polarity protection, grid monitoring, DC injection monitoring, return current monitoring, residual current detection, over temperature protection
Active anti-islanding method Frequency shifting Frequency shifting Frequency shifting Frequency shifting Frequency shifting
Surge protection (DC / AC) DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II

(1) Maximum DC input voltage is the upper limit. Exceeding this voltage may damage the inverter.
(2) Input voltage exceeding the MPPT voltage range may trigger the inverter protection.
(3) AC frequency range may vary depending on national regulations.
(4) Power reduction above +45°C.

Official distribution

Other brands in our portfolio