Inverter SOLAX X3-NEO-12K-LV

SKU: F20S122-1 EAN: 2010000034286
Manufacturer

Rated power

Power supply

Urządzenie hybrydowe

MPPT

2

AFCI

Optional

Gwarancja

Szerokość netto

Głębokość netto

Wysokość netto

Wi-Fi

Yes

RS485

Yes

CAN

Yes

USB

Yes

LAN

Yes

DRM

Yes

SPD Type II

Tryb pracy off-grid

Zakres napięcia MPPT

Weight 51,48 kg
CN 85044085
Price 1 999,05 
Gross

1 999,05 
Gross

In stock:

1 pcs
Login to place an order

1 999,05 
Gross

In stock:

1 pcs
Login to place an order

Product details

Manufacturer

Rated power

Power supply

Urządzenie hybrydowe

MPPT

2

AFCI

Optional

Gwarancja

Szerokość netto

Głębokość netto

Wysokość netto

Wi-Fi

Yes

RS485

Yes

CAN

Yes

USB

Yes

LAN

Yes

DRM

Yes

SPD Type II

Tryb pracy off-grid

Zakres napięcia MPPT

Weight 51,48 kg
CN 85044085

X3-NEO-LV Hybrid Inverter

The X3-NEO-LV series hybrid inverters are three-phase, low-voltage devices designed for residential applications, available in power variants from 5 to 15 kW. They combine intelligent energy management, high efficiency, and reliability, offering a comprehensive solution for storing and utilizing solar energy. With these inverters, it’s possible to optimize PV power usage and ensure power supply protection under all conditions.

Key Features of the X3-NEO-LV Hybrid Inverter:

  • Fast Switching Time: Emergency power supply (EPS) switch-over time under 1 ms, guaranteeing uninterrupted power.
  • High Efficiency and Power Flexibility: Supports up to 200% PV power oversizing and AC output up to 110%, with the ability to reach 200% EPS peak power for 10 seconds.
  • Advanced Energy Management: Global MPP scanning for optimal energy harvesting and maximum battery charge/discharge current ranging from 125 A to 300 A.
  • Reliable Operation: IP65 protection rating and built-in Type II SPD protection on both AC and DC sides, ensuring durability and safe operation across a wide temperature range from -25 to 60°C.
  • Installation Flexibility: Capability to connect up to 10 units in parallel in grid-tied and off-grid modes, featuring microgrid and generator modes for versatile operation.
  • Compatibility with High-Power Panels: Maximum DC input current per MPPT up to 36 A, optimized for modern high-power solar panels.

Who Is This a Good Choice For?

The X3-NEO-LV series inverters are an ideal solution for owners of single-family homes and small commercial facilities seeking a reliable and efficient energy management system. They are perfect for those looking to maximize solar self-consumption, ensure emergency power supply (EPS) with ultra-fast switching, and enjoy flexibility in expanding their photovoltaic system. Their high efficiency, robust protections, and smart communication features make them a comprehensive energy hub for the modern household.

Parameter X3-NEO-5K-LV X3-NEO-8K-LV X3-NEO-10K-LV X3-NEO-12K-LV X3-NEO-15K-LV
PV INPUT
Max. recommended PV panel array power (kWp) 10 16 20 24 30
Max. PV input voltage (V) 1000 1000 1000 1000 1000
Rated PV input voltage (V) 640 640 640 640 640
Operating voltage range (V) 160-950 160-950 160-950 160-950 160-950
MPPT voltage range (V) 160-950 160-950 160-950 160-950 160-950
Starting voltage (V) 150 150 150 150 150
Number of MPPT trackers / strings per MPPT tracker 2/(1/1) 2/(1/1) 2/(2/1) 2/(2/1) 2/(2/2)
Max. input current per MPPT (MPPT1/2) (A) 18/18 18/18 36/18 36/18 36/36
Max. short-circuit input current per MPPT (MPPT1/2) (A) 25/25 25/25 50/25 50/25 50/50
AC INPUT AND OUTPUT (GRID)
Rated output power (kW) 5 8 10 12 15
Rated output current (A) 7.3 11.6 14.5 15.3 17.4
Max. output apparent power (kVA) 5.5 8.8 11 13.2 16.5
Max. continuous output current (A) 8.4 13.4 16.8 20.0 25.0
Rated AC voltage (V) 3/N/PE, 220/380V
3/N/PE, 230/400V
3/N/PE, 220/380V
3/N/PE, 230/400V
3/N/PE, 220/380V
3/N/PE, 230/400V
3/N/PE, 220/380V
3/N/PE, 230/400V
3/N/PE, 220/380V
3/N/PE, 230/400V
Max. AC input apparent power (kVA) 10 16 20 24 30
Max. AC input current (A) 15.2 24.3 30.4 36.4 45.5
Rated AC frequency (Hz) 50/60 50/60 50/60 50/60 50/60
AC frequency range (Hz) 50±5 / 60±5 50±5 / 60±5 50±5 / 60±5 50±5 / 60±5 50±5 / 60±5
Adjustable power factor range -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading)
THDi (rated power) (%) <3 <3 <3 <3 <3
BATTERY
Battery type Lithium / Lead-acid battery Lithium / Lead-acid battery Lithium / Lead-acid battery Lithium / Lead-acid battery Lithium / Lead-acid battery
Battery voltage range (V) 40-60 40-60 40-60 40-60 40-60
Max. charging / discharging current (A) 125 200 250 280 300
EPS OUTPUT (OFF-GRID) (WITH BATTERY)
Rated EPS output power (kVA) 5 8 10 12 15
Peak EPS output power 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s
Switching time (ms) <1 <1 <1 <1 <1
EFFICIENCY
Max. efficiency (%) 97.6 97.6 97.6 97.6 97.6
European efficiency (%) 97.0 97.0 97.0 97.0 97.0
ENVIRONMENTAL LIMITS
Protection rating IP65 IP65 IP65 IP65 IP65
Operating ambient temperature range (°C) -25 to 60 -25 to 60 -25 to 60 -25 to 60 -25 to 60
Max. operating altitude (m) 3000 3000 3000 3000 3000
Relative humidity (% RH) 4-100 (condensation) 4-100 (condensation) 4-100 (condensation) 4-100 (condensation) 4-100 (condensation)
Surge category Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II
GENERAL
Dimensions (W × H × D) (mm) 520 × 705 × 258 520 × 705 × 258 520 × 705 × 258 520 × 705 × 258 520 × 705 × 258
Net weight (kg) 44.6 44.6 44.6 44.6 44.6
Cooling concept Intelligent cooling Intelligent cooling Intelligent cooling Intelligent cooling Intelligent cooling
Communication interfaces LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi + LAN LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi + LAN LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi + LAN LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi + LAN LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi + LAN
Power consumption (night) (W) <15 <15 <15 <15 <15
Topology Non-isolated Non-isolated Non-isolated Non-isolated Non-isolated
Certifications and approvals EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS
PROTECTION
Protection features Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse current monitoring, residual current detection, overheating protection Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse current monitoring, residual current detection, overheating protection Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse current monitoring, residual current detection, overheating protection Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse current monitoring, residual current detection, overheating protection Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse current monitoring, residual current detection, overheating protection
Active anti-islanding method Frequency shift Frequency shift Frequency shift Frequency shift Frequency shift
Surge protection (DC / AC) DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II

(1) The maximum DC input voltage is the upper limit. Exceeding this voltage may damage the inverter.
(2) Input voltage beyond the MPPT voltage range may trigger inverter protections.
(3) AC frequency range may vary depending on national requirements.
(4) Power reduction above +45°C.

Official distribution

Other brands in our portfolio