Inverter SOLAX X3-HYB-12.0-G4 Pro WiFi + Lan

SKU: F20S122 EAN: 2010000034187
Manufacturer

Rated power

Power supply

Urządzenie hybrydowe

MPPT

3

AFCI

Optional

Gwarancja

Szerokość netto

Głębokość netto

Wysokość netto

Wi-Fi

Yes

RS485

Yes

LAN

Yes

SPD Type II

Tryb pracy off-grid

Zakres napięcia MPPT

Weight 42,5 kg
CN 85044086
Price 2 013,85 
Gross

2 013,85 
Gross

In stock:

2 pcs
Login to place an order

2 013,85 
Gross

In stock:

2 pcs
Login to place an order

Product details

Manufacturer

Rated power

Power supply

Urządzenie hybrydowe

MPPT

3

AFCI

Optional

Gwarancja

Szerokość netto

Głębokość netto

Wysokość netto

Wi-Fi

Yes

RS485

Yes

LAN

Yes

SPD Type II

Tryb pracy off-grid

Zakres napięcia MPPT

Weight 42,5 kg
CN 85044086

Three-Phase Hybrid Inverter SolaX Power X3-HYB-G4 PRO

The three-phase hybrid inverter SolaX Power X3-HYB-G4 PRO is an advanced solution for residential properties, offering smart energy management and high efficiency. Available in a wide power range from 4 kW to 15 kW, it provides compatibility with V2H technology, intelligent scheduling, and wireless meter integration. With dual battery ports, a broad MPPT range, and the ability to handle 200% PV power oversizing, this device is flexible and reliable for maximizing self-consumption.

Key Features of the SolaX Power X3-HYB-G4 PRO Hybrid Inverter:

  • Smart Energy Management: V2H compatibility for smart home energy integration, Smart Schedule, Smart Scene, 7*24h TOU, and cooperation with VPP (OpenADR, IEEE2030.5, FCAS, API).
  • High Efficiency and PV Flexibility: DC input current of 20A per MPPT with 3 trackers, 200% PV oversizing capability, AC output up to 110%, and a very wide MPPT voltage range (110-950V).
  • Ensured Reliability and Safety: Up to 200% EPS output power for 10 seconds, UPS-level transfer time under 10 ms, optional rapid shutdown feature, type II SPD protection on AC and DC sides, and optional AFCI protection.
  • Flexible Adaptation Options: Dual battery ports and “2-in-1” expansion function, extra ports for easier wiring, and a functional, stylish cable cover.
  • Versatile Operating Modes: Supports microgrid and generator modes for diverse applications.
  • Performance Curve: High efficiency maintained across a wide load range, as demonstrated by the 15 kW model performance curve.

Who Is This a Good Choice For?

The SolaX Power X3-HYB-G4 PRO inverter is an excellent choice for single-family homeowners seeking an advanced, efficient, and reliable hybrid system. Its smart energy management features, high flexibility in PV and battery configurations, and extensive safety and adaptation options make it an ideal solution for maximizing self-consumption, ensuring backup power, and integrating with a smart home. The broad power range allows tailoring the device to individual energy needs.

 

Parameter X3-HYB-4.0-P X3-HYB-5.0-P X3-HYB-6.0-P X3-HYB-8.0-P X3-HYB-10.0-P X3-HYB-12.0-P X3-HYB-15.0-P
PV INPUT
Recommended max. power of PV panel array (kWp) 8 10 12 16 20 24 30
Max. PV input voltage (V) 1000 1000 1000 1000 1000 1000 1000
Nominal PV input voltage (V) 650 650 650 650 650 650 650
Operating voltage range (V) 110 – 950 110 – 950 110 – 950 110 – 950 110 – 950 110 – 950 110 – 950
MPPT voltage range (V) 110 – 950 110 – 950 110 – 950 110 – 950 110 – 950 110 – 950 110 – 950
Starting voltage (V) 120 120 120 120 120 120 120
Number of MPP trackers/strings per MPP tracker 2 (1 / 1) 2 (1 / 1) 2 (1 / 1) 3 (1 / 1 / 1) 3 (1 / 1 / 1) 3 (1 / 1 / 1) 3 (1 / 1 / 1)
Max. input current per MPPT (MPPT1/2/3) (A) 20 / 20 20 / 20 20 / 20 20 / 20 / 20 20 / 20 / 20 20 / 20 / 20 20 / 20 / 20
Max. short circuit input current per MPPT (MPPT1/2/3) (A) 25 / 25 25 / 25 25 / 25 25 / 25 / 25 25 / 25 / 25 25 / 25 / 25 25 / 25 / 25
AC INPUT & OUTPUT (GRID)
Rated output power (W) 4000 5000 (AS 4777 4999 W) 6000 8000 10000 (AS 4777 9999 W) 12000 15000 (AS 4777 14999 W)
Rated output current (A) 5.8 7.2 8.7 11.6 14.5 17.5 21.8
Max. output apparent power (VA) 4400 5500 (AS 4777 4999 VA) 6600 8800 11000 (AS 4777 9999 VA) 13200 16500 (AS 4777 14999 VA)
Max. continuous output current (A) 6.7 6.7 8.4 10.0 13.4 20.0 25.0
Nominal AC voltage 3/N/PE, 220/380 V; 3/N/PE, 230/400 V 3/N/PE, 220/380 V; 3/N/PE, 230/400 V 3/N/PE, 220/380 V; 3/N/PE, 230/400 V 3/N/PE, 220/380 V; 3/N/PE, 230/400 V 3/N/PE, 220/380 V; 3/N/PE, 230/400 V 3/N/PE, 220/380 V; 3/N/PE, 230/400 V 3/N/PE, 220/380 V; 3/N/PE, 230/400 V
Max. AC input apparent power (kVA) 8.4 10.5 12.6 16.8 21.0 21.0 21.0
Max. AC input current (A) 12.2 15.2 18.2 24.3 30.4 30.4 30.4
Nominal AC frequency (Hz) 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60 50 / 60
AC frequency range (Hz) 50 ± 5 / 60 ± 5 50 ± 5 / 60 ± 5 50 ± 5 / 60 ± 5 50 ± 5 / 60 ± 5 50 ± 5 / 60 ± 5 50 ± 5 / 60 ± 5 50 ± 5 / 60 ± 5
Adjustable power factor range -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading)
THDi (Rated Power) (%) <3 <3 <3 <3 <3 <3 <3
BATTERY
Battery type Lithium Lithium Lithium Lithium Lithium Lithium Lithium
Battery voltage range (V) 130 – 800 130 – 800 130 – 800 130 – 800 130 – 800 130 – 800 130 – 800
Max. charging / discharging current (A) 50 (25 x 2) 50 (25 x 2) 50 (25 x 2) 50 (25 x 2) 50 (25 x 2) 50 (25 x 2) 50 (25 x 2)
EPS OUTPUT (OFF-GRID) (WITH BATTERY)
Rated EPS output frequency 400 V / 230 V, 50 Hz / 60 Hz 400 V / 230 V, 50 Hz / 60 Hz 400 V / 230 V, 50 Hz / 60 Hz 400 V / 230 V, 50 Hz / 60 Hz 400 V / 230 V, 50 Hz / 60 Hz 400 V / 230 V, 50 Hz / 60 Hz 400 V / 230 V, 50 Hz / 60 Hz
Rated EPS output power (kVA) 4 5 6 8 10 12 15
EPS peak output power 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s
Switching time (ms) < 10 < 10 < 10 < 10 < 10 < 10 < 10
EFFICIENCY
Max. efficiency (%) 98.0 98.0 98.0 98.0 98.0 98.0 98.0
European efficiency (%) 97.7 97.7 97.7 97.7 97.7 97.7 97.7
ENVIRONMENTAL LIMITS
Protection rating IP66 IP66 IP66 IP66 IP66 IP66 IP66
Operating ambient temperature range (°C) -35 – 60 -35 – 60 -35 – 60 -35 – 60 -35 – 60 -35 – 60 -35 – 60
Max. operating altitude (m) 3000 3000 3000 3000 3000 3000 3000
Relative humidity 0 – 100% RH (condensation) 0 – 100% RH (condensation) 0 – 100% RH (condensation) 0 – 100% RH (condensation) 0 – 100% RH (condensation) 0 – 100% RH (condensation) 0 – 100% RH (condensation)
Surge category Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II
GENERAL
Dimensions (W x H x D) (mm) 560 x 503 x 210 560 x 503 x 210 560 x 503 x 210 560 x 503 x 210 560 x 503 x 210 560 x 503 x 210 560 x 503 x 210
Net weight (kg) 38 38 38 38 38 38 38
Cooling concept Natural cooling Natural cooling Natural cooling Intelligent cooling Intelligent cooling Intelligent cooling Intelligent cooling
Communication interfaces COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat Pump) COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat Pump) COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat Pump) COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat Pump) COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat Pump) COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat Pump) COM1 (Parallel 1, Parallel 2, BMS 1, BMS 2, RS485, METER / CT); COM2 (DI/DO, EVC, DATAHUB, DRM, V2X, Heat Pump)
Power consumption (night) (W) < 40W standby, < 5W idle < 40W standby, < 5W idle < 40W standby, < 5W idle < 40W standby, < 5W idle < 40W standby, < 5W idle < 40W standby, < 5W idle < 40W standby, < 5W idle
Topology Non-isolated Non-isolated Non-isolated Non-isolated Non-isolated Non-isolated Non-isolated
Certifications and approvals IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21 IEC62109-1/IEC62109-2, VDE 0126-1-1 A1:2012, VDE-AR-N 4105, G98, G99, AS4777, EN50549, CEI 0-21
Auxiliary AC power supply (APS) Built-in Built-in Built-in Built-in Built-in Built-in Built-in
PROTECTION
Protection Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short circuit protection Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short circuit protection Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short circuit protection Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short circuit protection Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short circuit protection Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short circuit protection Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, Grid monitoring, DC injection monitoring, Reverse current monitoring, Residual current detection, Over-temperature protection, AC overvoltage protection, AC short circuit protection
Active anti-islanding method Frequency shift Frequency shift Frequency shift Frequency shift Frequency shift Frequency shift Frequency shift
Surge protection (DC / AC) DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II
Arc Fault Circuit Interrupter (AFCI) Optional Optional Optional Optional Optional Optional Optional

Notes:

① The maximum input voltage is the upper limit of the DC voltage. Any DC input voltage above this limit may damage the inverter.

② Input voltage exceeding the MPPT voltage range may trigger the inverter’s protection.

③ AC frequency range may vary according to different country codes.

④ If each of the two battery ports is connected to a separate battery, the current is 25 A per port. If one port is connected to a single battery, the current is 30 A. If both ports are connected to one battery using a 2-in-1 splitter cable (sold separately), the current is 50 A.

⑤ Derated value at +45°C.

Official distribution