Inverter SOLAX X3-NEO-15K-LV
Manufacturer | |
---|---|
Rated power | |
Power supply | |
Urządzenie hybrydowe | |
MPPT | 2 |
AFCI | Optional |
Gwarancja | |
Szerokość netto | |
Głębokość netto | |
Wysokość netto | |
Wi-Fi | Yes |
RS485 | Yes |
CAN | Yes |
USB | Yes |
LAN | Yes |
DRM | Yes |
SPD Type II | |
Tryb pracy off-grid | |
Zakres napięcia MPPT | |
Weight | 51,14 kg |
CN | 85044085 |
Gross
Product details
Manufacturer | |
---|---|
Rated power | |
Power supply | |
Urządzenie hybrydowe | |
MPPT | 2 |
AFCI | Optional |
Gwarancja | |
Szerokość netto | |
Głębokość netto | |
Wysokość netto | |
Wi-Fi | Yes |
RS485 | Yes |
CAN | Yes |
USB | Yes |
LAN | Yes |
DRM | Yes |
SPD Type II | |
Tryb pracy off-grid | |
Zakres napięcia MPPT | |
Weight | 51,14 kg |
CN | 85044085 |
X3-NEO-LV Hybrid Inverter
The X3-NEO-LV series hybrid inverters are three-phase, low-voltage devices designed for residential use, available in power variants ranging from 5 to 15 kW. They combine intelligent energy management, high efficiency, and reliability, offering a comprehensive solution for storing and utilizing solar energy. With these inverters, you can optimize PV power usage and ensure power supply security under any conditions.
Key Features of the X3-NEO-LV Hybrid Inverter:
- Fast switching time: Emergency power supply (EPS) switching time under 1 ms, ensuring uninterrupted power.
- High efficiency and power flexibility: Supports up to 200% PV power overload and AC output up to 110%, with the ability to reach 200% EPS peak power for 10 seconds.
- Advanced energy management: Global MPP scanning for optimal energy harvesting and a maximum battery charge/discharge current ranging from 125 A to 300 A.
- Reliable operation guaranteed: IP65 protection rating and integrated Type II SPD protection on AC and DC sides, ensuring durability and safe operation across a wide temperature range from -25 to 60°C.
- Installation flexibility: Ability to connect up to 10 units in parallel both on-grid and off-grid, with microgrid and generator mode functions for versatile operation.
- Compatibility with high-power panels: Maximum DC input current per MPPT up to 36 A, optimized for modern high-power solar panels.
Who is this a good choice for?
The X3-NEO-LV series inverters are an ideal solution for homeowners and small commercial properties seeking a reliable and efficient energy management system. They are perfect for those aiming to maximize self-consumption of solar energy, ensure emergency power supply (EPS) with ultra-fast switching, and gain flexibility in expanding their photovoltaic system. Their high efficiency, robust protections, and intelligent communication features make them a comprehensive energy hub for the modern household.
Parameter | X3-NEO-5K-LV | X3-NEO-8K-LV | X3-NEO-10K-LV | X3-NEO-12K-LV | X3-NEO-15K-LV |
---|---|---|---|---|---|
PV INPUT | |||||
Max. recommended PV panel array power (kWp) | 10 | 16 | 20 | 24 | 30 |
Max. PV input voltage (V) | 1000 | 1000 | 1000 | 1000 | 1000 |
Rated PV input voltage (V) | 640 | 640 | 640 | 640 | 640 |
Operating voltage range (V) | 160-950 | 160-950 | 160-950 | 160-950 | 160-950 |
MPPT voltage range (V) | 160-950 | 160-950 | 160-950 | 160-950 | 160-950 |
Starting voltage (V) | 150 | 150 | 150 | 150 | 150 |
Number of MPP trackers / strings per MPP tracker | 2/(1/1) | 2/(1/1) | 2/(2/1) | 2/(2/1) | 2/(2/2) |
Max. input current per MPPT (MPPT1/2) (A) | 18/18 | 18/18 | 36/18 | 36/18 | 36/36 |
Max. short-circuit input current per MPPT (MPPT1/2) (A) | 25/25 | 25/25 | 50/25 | 50/25 | 50/50 |
AC INPUT & OUTPUT (GRID) | |||||
Rated output power (kW) | 5 | 8 | 10 | 12 | 15 |
Rated output current (A) | 7.3 | 11.6 | 14.5 | 15.3 | 17.4 |
Max. output apparent power (kVA) | 5.5 | 8.8 | 11 | 13.2 | 16.5 |
Max. continuous output current (A) | 8.4 | 13.4 | 16.8 | 20.0 | 25.0 |
Rated AC voltage (V) | 3/N/PE, 220/380V 3/N/PE, 230/400V |
3/N/PE, 220/380V 3/N/PE, 230/400V |
3/N/PE, 220/380V 3/N/PE, 230/400V |
3/N/PE, 220/380V 3/N/PE, 230/400V |
3/N/PE, 220/380V 3/N/PE, 230/400V |
Max. AC input apparent power (kVA) | 10 | 16 | 20 | 24 | 30 |
Max. AC input current (A) | 15.2 | 24.3 | 30.4 | 36.4 | 45.5 |
Rated AC frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
AC frequency range (Hz) | 50±5 / 60±5 | 50±5 / 60±5 | 50±5 / 60±5 | 50±5 / 60±5 | 50±5 / 60±5 |
Adjustable power factor range | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) |
THDi (rated power) (%) | <3 | <3 | <3 | <3 | <3 |
BATTERY | |||||
Battery type | Lithium / Lead-acid battery | Lithium / Lead-acid battery | Lithium / Lead-acid battery | Lithium / Lead-acid battery | Lithium / Lead-acid battery |
Battery voltage range (V) | 40-60 | 40-60 | 40-60 | 40-60 | 40-60 |
Max. charging / discharging current (A) | 125 | 200 | 250 | 280 | 300 |
EPS OUTPUT (OFF-GRID) (WITH BATTERY) | |||||
Rated EPS output power (kVA) | 5 | 8 | 10 | 12 | 15 |
Peak EPS output power | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s |
Switching time (ms) | <1 | <1 | <1 | <1 | <1 |
EFFICIENCY | |||||
Max. efficiency (%) | 97.6 | 97.6 | 97.6 | 97.6 | 97.6 |
European efficiency (%) | 97.0 | 97.0 | 97.0 | 97.0 | 97.0 |
ENVIRONMENTAL LIMITS | |||||
Protection rating | IP65 | IP65 | IP65 | IP65 | IP65 |
Operating ambient temperature range (°C) | -25 to 60 | -25 to 60 | -25 to 60 | -25 to 60 | -25 to 60 |
Max. operating altitude (m) | 3000 | 3000 | 3000 | 3000 | 3000 |
Relative humidity (% RH) | 4-100 (condensing) | 4-100 (condensing) | 4-100 (condensing) | 4-100 (condensing) | 4-100 (condensing) |
Surge category | Grid: III, Battery: II, PV: II | Grid: III, Battery: II, PV: II | Grid: III, Battery: II, PV: II | Grid: III, Battery: II, PV: II | Grid: III, Battery: II, PV: II |
GENERAL | |||||
Dimensions (W × H × D) (mm) | 520 × 705 × 258 | 520 × 705 × 258 | 520 × 705 × 258 | 520 × 705 × 258 | 520 × 705 × 258 |
Net weight (kg) | 44.6 | 44.6 | 44.6 | 44.6 | 44.6 |
Cooling concept | Intelligent cooling | Intelligent cooling | Intelligent cooling | Intelligent cooling | Intelligent cooling |
Communication interfaces | LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN | LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN | LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN | LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN | LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN |
Power consumption (night) (W) | <15 | <15 | <15 | <15 | <15 |
Topology | Non-isolated | Non-isolated | Non-isolated | Non-isolated | Non-isolated |
Certifications and approvals | EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS | EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS | EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS | EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS | EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS |
PROTECTION | |||||
Protective features | Overvoltage / undervoltage protection, DC insulation monitoring, DC reverse polarity protection, grid monitoring, DC injection monitoring, return current monitoring, residual current detection, over temperature protection | Overvoltage / undervoltage protection, DC insulation monitoring, DC reverse polarity protection, grid monitoring, DC injection monitoring, return current monitoring, residual current detection, over temperature protection | Overvoltage / undervoltage protection, DC insulation monitoring, DC reverse polarity protection, grid monitoring, DC injection monitoring, return current monitoring, residual current detection, over temperature protection | Overvoltage / undervoltage protection, DC insulation monitoring, DC reverse polarity protection, grid monitoring, DC injection monitoring, return current monitoring, residual current detection, over temperature protection | Overvoltage / undervoltage protection, DC insulation monitoring, DC reverse polarity protection, grid monitoring, DC injection monitoring, return current monitoring, residual current detection, over temperature protection |
Active anti-islanding method | Frequency shifting | Frequency shifting | Frequency shifting | Frequency shifting | Frequency shifting |
Surge protection (DC / AC) | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II |
(1) Maximum DC input voltage is the upper limit. Exceeding this voltage may damage the inverter.
(2) Input voltage exceeding the MPPT voltage range may trigger the inverter protection.
(3) AC frequency range may vary depending on national regulations.
(4) Power reduction above +45°C.