Inverter SOLAX X3-NEO-12K-LV
Manufacturer | |
---|---|
Rated power | |
Power supply | |
Urządzenie hybrydowe | |
MPPT | 2 |
AFCI | Optional |
Gwarancja | |
Szerokość netto | |
Głębokość netto | |
Wysokość netto | |
Wi-Fi | Yes |
RS485 | Yes |
CAN | Yes |
USB | Yes |
LAN | Yes |
DRM | Yes |
SPD Type II | |
Tryb pracy off-grid | |
Zakres napięcia MPPT | |
Weight | 51,48 kg |
CN | 85044085 |
Gross
Product details
Manufacturer | |
---|---|
Rated power | |
Power supply | |
Urządzenie hybrydowe | |
MPPT | 2 |
AFCI | Optional |
Gwarancja | |
Szerokość netto | |
Głębokość netto | |
Wysokość netto | |
Wi-Fi | Yes |
RS485 | Yes |
CAN | Yes |
USB | Yes |
LAN | Yes |
DRM | Yes |
SPD Type II | |
Tryb pracy off-grid | |
Zakres napięcia MPPT | |
Weight | 51,48 kg |
CN | 85044085 |
X3-NEO-LV Hybrid Inverter
The X3-NEO-LV series hybrid inverters are three-phase, low-voltage devices designed for residential applications, available in power variants from 5 to 15 kW. They combine intelligent energy management, high efficiency, and reliability, offering a comprehensive solution for storing and utilizing solar energy. With these inverters, it’s possible to optimize PV power usage and ensure power supply protection under all conditions.
Key Features of the X3-NEO-LV Hybrid Inverter:
- Fast Switching Time: Emergency power supply (EPS) switch-over time under 1 ms, guaranteeing uninterrupted power.
- High Efficiency and Power Flexibility: Supports up to 200% PV power oversizing and AC output up to 110%, with the ability to reach 200% EPS peak power for 10 seconds.
- Advanced Energy Management: Global MPP scanning for optimal energy harvesting and maximum battery charge/discharge current ranging from 125 A to 300 A.
- Reliable Operation: IP65 protection rating and built-in Type II SPD protection on both AC and DC sides, ensuring durability and safe operation across a wide temperature range from -25 to 60°C.
- Installation Flexibility: Capability to connect up to 10 units in parallel in grid-tied and off-grid modes, featuring microgrid and generator modes for versatile operation.
- Compatibility with High-Power Panels: Maximum DC input current per MPPT up to 36 A, optimized for modern high-power solar panels.
Who Is This a Good Choice For?
The X3-NEO-LV series inverters are an ideal solution for owners of single-family homes and small commercial facilities seeking a reliable and efficient energy management system. They are perfect for those looking to maximize solar self-consumption, ensure emergency power supply (EPS) with ultra-fast switching, and enjoy flexibility in expanding their photovoltaic system. Their high efficiency, robust protections, and smart communication features make them a comprehensive energy hub for the modern household.
Parameter | X3-NEO-5K-LV | X3-NEO-8K-LV | X3-NEO-10K-LV | X3-NEO-12K-LV | X3-NEO-15K-LV |
---|---|---|---|---|---|
PV INPUT | |||||
Max. recommended PV panel array power (kWp) | 10 | 16 | 20 | 24 | 30 |
Max. PV input voltage (V) | 1000 | 1000 | 1000 | 1000 | 1000 |
Rated PV input voltage (V) | 640 | 640 | 640 | 640 | 640 |
Operating voltage range (V) | 160-950 | 160-950 | 160-950 | 160-950 | 160-950 |
MPPT voltage range (V) | 160-950 | 160-950 | 160-950 | 160-950 | 160-950 |
Starting voltage (V) | 150 | 150 | 150 | 150 | 150 |
Number of MPPT trackers / strings per MPPT tracker | 2/(1/1) | 2/(1/1) | 2/(2/1) | 2/(2/1) | 2/(2/2) |
Max. input current per MPPT (MPPT1/2) (A) | 18/18 | 18/18 | 36/18 | 36/18 | 36/36 |
Max. short-circuit input current per MPPT (MPPT1/2) (A) | 25/25 | 25/25 | 50/25 | 50/25 | 50/50 |
AC INPUT AND OUTPUT (GRID) | |||||
Rated output power (kW) | 5 | 8 | 10 | 12 | 15 |
Rated output current (A) | 7.3 | 11.6 | 14.5 | 15.3 | 17.4 |
Max. output apparent power (kVA) | 5.5 | 8.8 | 11 | 13.2 | 16.5 |
Max. continuous output current (A) | 8.4 | 13.4 | 16.8 | 20.0 | 25.0 |
Rated AC voltage (V) | 3/N/PE, 220/380V 3/N/PE, 230/400V |
3/N/PE, 220/380V 3/N/PE, 230/400V |
3/N/PE, 220/380V 3/N/PE, 230/400V |
3/N/PE, 220/380V 3/N/PE, 230/400V |
3/N/PE, 220/380V 3/N/PE, 230/400V |
Max. AC input apparent power (kVA) | 10 | 16 | 20 | 24 | 30 |
Max. AC input current (A) | 15.2 | 24.3 | 30.4 | 36.4 | 45.5 |
Rated AC frequency (Hz) | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
AC frequency range (Hz) | 50±5 / 60±5 | 50±5 / 60±5 | 50±5 / 60±5 | 50±5 / 60±5 | 50±5 / 60±5 |
Adjustable power factor range | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) | -1 (0.8 lagging to 0.8 leading) |
THDi (rated power) (%) | <3 | <3 | <3 | <3 | <3 |
BATTERY | |||||
Battery type | Lithium / Lead-acid battery | Lithium / Lead-acid battery | Lithium / Lead-acid battery | Lithium / Lead-acid battery | Lithium / Lead-acid battery |
Battery voltage range (V) | 40-60 | 40-60 | 40-60 | 40-60 | 40-60 |
Max. charging / discharging current (A) | 125 | 200 | 250 | 280 | 300 |
EPS OUTPUT (OFF-GRID) (WITH BATTERY) | |||||
Rated EPS output power (kVA) | 5 | 8 | 10 | 12 | 15 |
Peak EPS output power | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s | 2 times rated power, 10 s |
Switching time (ms) | <1 | <1 | <1 | <1 | <1 |
EFFICIENCY | |||||
Max. efficiency (%) | 97.6 | 97.6 | 97.6 | 97.6 | 97.6 |
European efficiency (%) | 97.0 | 97.0 | 97.0 | 97.0 | 97.0 |
ENVIRONMENTAL LIMITS | |||||
Protection rating | IP65 | IP65 | IP65 | IP65 | IP65 |
Operating ambient temperature range (°C) | -25 to 60 | -25 to 60 | -25 to 60 | -25 to 60 | -25 to 60 |
Max. operating altitude (m) | 3000 | 3000 | 3000 | 3000 | 3000 |
Relative humidity (% RH) | 4-100 (condensation) | 4-100 (condensation) | 4-100 (condensation) | 4-100 (condensation) | 4-100 (condensation) |
Surge category | Grid: III, Battery: II, PV: II | Grid: III, Battery: II, PV: II | Grid: III, Battery: II, PV: II | Grid: III, Battery: II, PV: II | Grid: III, Battery: II, PV: II |
GENERAL | |||||
Dimensions (W × H × D) (mm) | 520 × 705 × 258 | 520 × 705 × 258 | 520 × 705 × 258 | 520 × 705 × 258 | 520 × 705 × 258 |
Net weight (kg) | 44.6 | 44.6 | 44.6 | 44.6 | 44.6 |
Cooling concept | Intelligent cooling | Intelligent cooling | Intelligent cooling | Intelligent cooling | Intelligent cooling |
Communication interfaces | LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi + LAN | LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi + LAN | LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi + LAN | LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi + LAN | LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi + LAN |
Power consumption (night) (W) | <15 | <15 | <15 | <15 | <15 |
Topology | Non-isolated | Non-isolated | Non-isolated | Non-isolated | Non-isolated |
Certifications and approvals | EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS | EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS | EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS | EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS | EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS |
PROTECTION | |||||
Protection features | Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse current monitoring, residual current detection, overheating protection | Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse current monitoring, residual current detection, overheating protection | Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse current monitoring, residual current detection, overheating protection | Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse current monitoring, residual current detection, overheating protection | Overvoltage / undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse current monitoring, residual current detection, overheating protection |
Active anti-islanding method | Frequency shift | Frequency shift | Frequency shift | Frequency shift | Frequency shift |
Surge protection (DC / AC) | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II | DC: Type II, AC: Type II |
(1) The maximum DC input voltage is the upper limit. Exceeding this voltage may damage the inverter.
(2) Input voltage beyond the MPPT voltage range may trigger inverter protections.
(3) AC frequency range may vary depending on national requirements.
(4) Power reduction above +45°C.