Inverter SOLAX X3-NEO-5K-LV

SKU: F20S01 EAN: 2010000034255
Manufacturer

Rated power

Power supply

Urządzenie hybrydowe

MPPT

2

AFCI

Optional

Gwarancja

Szerokość netto

Głębokość netto

Wysokość netto

Wi-Fi

Yes

RS485

Yes

CAN

Yes

USB

Yes

LAN

Yes

DRM

Yes

SPD Type II

Tryb pracy off-grid

Zakres napięcia MPPT

Weight 44,34 kg
CN 85044085
Price 1 702,89 
Gross

1 702,89 
Gross

Email when stock available

1 702,89 
Gross

Email when stock available

Product details

Manufacturer

Rated power

Power supply

Urządzenie hybrydowe

MPPT

2

AFCI

Optional

Gwarancja

Szerokość netto

Głębokość netto

Wysokość netto

Wi-Fi

Yes

RS485

Yes

CAN

Yes

USB

Yes

LAN

Yes

DRM

Yes

SPD Type II

Tryb pracy off-grid

Zakres napięcia MPPT

Weight 44,34 kg
CN 85044085

Hybrid Inverter X3-NEO-LV

The X3-NEO-LV series hybrid inverters are three-phase, low-voltage devices designed for residential use, available in power variants ranging from 5 to 15 kW. They combine intelligent energy management, high efficiency, and reliability, offering a comprehensive solution for storing and utilizing solar energy. With these inverters, you can optimize PV power usage and ensure power supply protection under all conditions.

Key Features of the Hybrid Inverter X3-NEO-LV:

  • Fast Switching Time: Emergency power supply (EPS) switching time below 1 ms, ensuring continuous power supply.
  • High Efficiency and Power Flexibility: Supports up to 200% PV power surplus and AC output up to 110%, with the ability to reach 200% EPS peak power for 10 seconds.
  • Advanced Energy Management: Global MPP scanning for optimal energy harvesting and maximum battery charge/discharge current ranging from 125 A to 300 A.
  • Reliable Protection: IP65 protection rating and integrated Type II SPD protection on both AC and DC sides, ensuring durability and safe operation in a wide temperature range from -25 to 60°C.
  • Installation Flexibility: Can connect up to 10 units in parallel in both grid-tied and off-grid modes, featuring microgrid and generator modes for versatile operation.
  • Compatible with High-Power Panels: Maximum DC input current per MPPT up to 36 A, optimized for modern high-power solar panels.

Who Is This a Good Choice For?

The X3-NEO-LV series inverters are an ideal solution for homeowners and small commercial properties looking for a reliable and efficient energy management system. They are perfect for those aiming to maximize self-consumption of solar energy, ensure emergency power supply (EPS) with ultra-fast switching, and enjoy flexibility in expanding their photovoltaic system. Their high efficiency, robust protections, and smart communication features make them a comprehensive energy hub for a modern household.

Parameter X3-NEO-5K-LV X3-NEO-8K-LV X3-NEO-10K-LV X3-NEO-12K-LV X3-NEO-15K-LV
PV INPUT
Max. recommended PV panel array power (kWp) 10 16 20 24 30
Max. PV input voltage (V) 1000 1000 1000 1000 1000
Rated PV input voltage (V) 640 640 640 640 640
Operating voltage range (V) 160-950 160-950 160-950 160-950 160-950
MPPT voltage range (V) 160-950 160-950 160-950 160-950 160-950
Starting voltage (V) 150 150 150 150 150
Number of MPP trackers / strings per MPP tracker 2/(1/1) 2/(1/1) 2/(2/1) 2/(2/1) 2/(2/2)
Max. input current per MPPT (MPPT1/2) (A) 18/18 18/18 36/18 36/18 36/36
Max. short-circuit input current per MPPT (MPPT1/2) (A) 25/25 25/25 50/25 50/25 50/50
AC INPUT AND OUTPUT (GRID-TIED)
Rated output power (kW) 5 8 10 12 15
Rated output current (A) 7.3 11.6 14.5 15.3 17.4
Max. apparent output power (kVA) 5.5 8.8 11 13.2 16.5
Max. continuous output current (A) 8.4 13.4 16.8 20.0 25.0
Rated AC voltage (V) 3/N/PE, 220/380V
3/N/PE, 230/400V
3/N/PE, 220/380V
3/N/PE, 230/400V
3/N/PE, 220/380V
3/N/PE, 230/400V
3/N/PE, 220/380V
3/N/PE, 230/400V
3/N/PE, 220/380V
3/N/PE, 230/400V
Max. apparent AC input power (kVA) 10 16 20 24 30
Max. AC input current (A) 15.2 24.3 30.4 36.4 45.5
Rated AC frequency (Hz) 50/60 50/60 50/60 50/60 50/60
AC frequency range (Hz) 50±5 / 60±5 50±5 / 60±5 50±5 / 60±5 50±5 / 60±5 50±5 / 60±5
Adjustable power factor range -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading) -1 (0.8 lagging to 0.8 leading)
THDi (rated power) (%) <3 <3 <3 <3 <3
BATTERY
Battery type Lithium battery / Lead-acid battery Lithium battery / Lead-acid battery Lithium battery / Lead-acid battery Lithium battery / Lead-acid battery Lithium battery / Lead-acid battery
Battery voltage range (V) 40-60 40-60 40-60 40-60 40-60
Max. charge/discharge current (A) 125 200 250 280 300
EPS OUTPUT (OFF-GRID) (WITH BATTERY)
Rated EPS output power (kVA) 5 8 10 12 15
Peak EPS output power 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s 2 times rated power, 10 s
Switching time (ms) <1 <1 <1 <1 <1
EFFICIENCY
Max. efficiency (%) 97.6 97.6 97.6 97.6 97.6
European efficiency (%) 97.0 97.0 97.0 97.0 97.0
ENVIRONMENTAL LIMITS
Protection degree IP65 IP65 IP65 IP65 IP65
Operating ambient temperature range (°C) -25 to 60 -25 to 60 -25 to 60 -25 to 60 -25 to 60
Max. operating altitude (m) 3000 3000 3000 3000 3000
Relative humidity (% RH) 4-100 (condensing) 4-100 (condensing) 4-100 (condensing) 4-100 (condensing) 4-100 (condensing)
Surge category Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II Grid: III, Battery: II, PV: II
GENERAL
Dimensions (W × H × D) (mm) 520 × 705 × 258 520 × 705 × 258 520 × 705 × 258 520 × 705 × 258 520 × 705 × 258
Net weight (kg) 44.6 44.6 44.6 44.6 44.6
Cooling concept Intelligent cooling Intelligent cooling Intelligent cooling Intelligent cooling Intelligent cooling
Communication interfaces LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN LED + LCD / CAN, RS485, CT, Meter, NTC, WiFi+LAN
Power consumption (night) (W) <15 <15 <15 <15 <15
Topology Non-isolated Non-isolated Non-isolated Non-isolated Non-isolated
Certifications and approvals EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS EN IEC 62109-1 / -2, NRS 097-2-1, IEC 61727, IEC 62116, PEA, MEA, BIS
PROTECTION
Protections Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse leakage current monitoring, residual current detection, over-temperature protection Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse leakage current monitoring, residual current detection, over-temperature protection Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse leakage current monitoring, residual current detection, over-temperature protection Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse leakage current monitoring, residual current detection, over-temperature protection Overvoltage/undervoltage protection, DC isolation protection, DC reverse polarity protection, grid monitoring, DC injection monitoring, reverse leakage current monitoring, residual current detection, over-temperature protection
Active anti-islanding method Frequency shift Frequency shift Frequency shift Frequency shift Frequency shift
Surge protection (DC / AC) DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II DC: Type II, AC: Type II

(1) Maximum DC input voltage is the upper limit. Higher DC input voltage may damage the inverter.
(2) Input voltage exceeding the MPPT voltage range may trigger inverter protections.
(3) AC frequency range may vary depending on national requirements.
(4) Power derating above +45°C.

Official distribution